Applied Nursing Research
Volume 24, Issue 4 , Pages e39-e43 , November 2011

Comparison of oxygen saturation values and measurement times by pulse oximetry in various parts of the body

Received 28 April 2009 ,Revised 23 February 2010 ,Accepted 8 March 2010.

References 

  1. Bambi S, Orlandi I, Lumini E, Becattini G. Forehead oximetry: Another (little) brick in the wall. Heart & Lung. 2008;76:January-February
  2. Branson RD, Mannheimer PD. Forehead oximetry in critically ill patients: The case for a new monitoring site. Respiratory Care Clinics of North America. 2004;10(3):359–367
  3. Fernandez M, Burns K, Calhoun B, George S, Martin B, Weaver C. Evaluation of a new pulse oximeter sensor. American Journal of Critical Care. 2007;16(2):146–152
  4. Giuliano KK, Higgins TL. New-generation pulse oximetry in the care of critically ill patients. American Journal of Critical Care. 2005;14(1):26–39
  5. Hakemi A, Bender JA. Understanding pulse oximetry, advantages, and limitations. Home Health Care Management & Practice. 2005;17(5):416–418
  6. Hinkelbein J, Genzwuerker HV, Sogl R, Fiedler F. Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients. Resuscitation. 2006;72(1):82–91
  7. Jensen LA, Onyskiw JE, Prasad NGN. Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults. Hearth & Lung: Journal of Acute & Critical Care. 1998;27(6):387–408
  8. Jubran A. Pulse oximetry. Critical Care. 1999;3(2):11–17
  9. MacLeod DB, Cortinez LI, Keifer JC, Cameron D, Wright DR, White WD, et al. The desaturation response time of finger pulse oximeters during mild hypothermia. Anaesthhesia. 2005;60:65–71
  10. Mannheimer PD, Bebout DE. The oxiMax system. Nellcor's new platform for pulse oximetry. Minerva Anestesiol. 2002;68(4):236–239
  11. Nuhr M, Hoerauf K, Joldzo A, Frickey N, Barker R, Gorove L, et al. Forehead SaO2 monitoring compared to finger SaO2 recording in emergency transport. Anaesthesia. 2004;59:390–393
  12. Rodden AM, Spicer L, Diaz VA, Steyer TE. Does fingernail polish affect pulse oximeter readings. Intensive and Critical Care Nursing. 2006;23(1):51–55
  13. Schallom L, Sona C, McSweeney M, Mazuski J. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion. Hearth & Lung. 2007;36:188–194
  14. Schutz SL. Oxygen saturation monitoring by pulse oximetry. In:  Lynn-McHale DJ,  Carlson KK editor. AACN Procedure manual for critical care. 4th ed. W.B.Saunders; 2001;p. 77–82
  15. Simon SB, Clark RA. (Mis) Using pulse oximetry: A review of pulse oximetry use in acute care medical wards. Clinical Effectiveness in Nursing. 2002;6:106–110
  16. Sugino S, Kanaya N, Mizuuchi M, Nakayama M, Namiki A. Forehead is as sensitive as finger pulse oximetry during general anesthesia. Canadian Journal of Anesthesia. 2004;51(5):432–436
  17. Sun SW, Patel B, Gangoo W, Carrey Z. Reliability of forehead pulse oximetry in critically ill patients. Chest. 2003;124(4):178
  18. Tucker SM, Canobbio MM, Paquette EV, Wells MF. Respiratory system, patient care standards: Collaborative planning & nursing interventions. 7th ed.. A Harcourt Health Sciences Company; 2000;Printed in United States of America
  19. Woodrow P. Pulse oximetry. Nursing Standard. 1999;13:42–47

PII: S0897-1897(10)00029-7

doi: 10.1016/j.apnr.2010.03.002

Applied Nursing Research
Volume 24, Issue 4 , Pages e39-e43 , November 2011